    Introduction

    Fields

    Stored in cfnProcData

    SMF FieldDB Column nameDescriptionUnit
    recordTypeValue is always XCPU
    SMF74SIDsidSystem identification (from the SID parameter)
    SMF74GIEstartTimeProjected gathering interval end GMT time
    SMF74TMEendTimeTime since midnight, in hundredths of a second, that the record was moved into the SMF buffer
    SMF74INTsecondsDuration of the RMF measurement intervalsecond
    SMF74MFVrmfVersionRMF Version number
    SMF74PRDproductNameProduct name (‘RMF’)
    SMF74MVSmvsLevelMVS software level (ZVvvrrmm)
    SMF74IMLprocessorTypeIndicates the type of processor complex on which data measurements were taken
    SMF74PRFprocessorFlagsProcessor flags (0, 1, 2, 3, 4, 5, 6 or 7)
    offset
    SMF74SYNsynctimeSYNC valuesecond
    SMF74XNMsysplexSysplex name ( in the COUPLExx parmlib member)
    SMF74SNMsysnameSystem name (r in the IEASYSxx parmlib member)
    R744PNUMcfProcCpuNumCPU number
    R744PBSYcfProcBusyTimeBusy timemicrosecond
    R744PWAIcfProcWaitTimeWait timemicrosecond
    R744PTYPcfProcFlagsProcessor flags
    R744PWGTcfProcWgt0 means Processor is dedicated
    actionId
    R744FNAMElcfCFNameName of coupling facility as defined in parmlib member COUPLExx

    Changing your password will log you out immediately. Use the new password to log back in.
    First name must have atleast 2 characters. Numbers and special characters are not allowed.
    Last name must have atleast 1 characters. Numbers and special characters are not allowed.
    Enter a valid email
    Enter a valid password
    Your profile has been successfully updated.