SMF 74-4 Processor Utilization

Prev Next

Introduction

Fields

Stored in cfnProcData

SMF Field DB Column name Description Unit
recordType Value is always XCPU
SMF74SID sid System identification (from the SID parameter)
SMF74GIE startTime Projected gathering interval end GMT time
SMF74TME endTime Time since midnight, in hundredths of a second, that the record was moved into the SMF buffer
SMF74INT seconds Duration of the RMF measurement interval second
SMF74MFV rmfVersion RMF Version number
SMF74PRD productName Product name (‘RMF’)
SMF74MVS mvsLevel MVS software level (ZVvvrrmm)
SMF74IML processorType Indicates the type of processor complex on which data measurements were taken
SMF74PRF processorFlags Processor flags (0, 1, 2, 3, 4, 5, 6 or 7)
offset
SMF74SYN synctime SYNC value second
SMF74XNM sysplex Sysplex name ( in the COUPLExx parmlib member)
SMF74SNM sysname System name (r in the IEASYSxx parmlib member)
R744PNUM cfProcCpuNum CPU number
R744PBSY cfProcBusyTime Busy time microsecond
R744PWAI cfProcWaitTime Wait time microsecond
R744PTYP cfProcFlags Processor flags
R744PWGT cfProcWgt 0 means Processor is dedicated
actionId
R744FNAME lcfCFName Name of coupling facility as defined in parmlib member COUPLExx