- Print
- DarkLight
SMF 75 RMF Page Data Set Activity
Article summary
Did you find this summary helpful?
Thank you for your feedback
Introduction
Fields
Stored in pageData
SMF Field | DB Column name | Description | Unit |
---|---|---|---|
recordType | Value is always ME75 | ||
SMF75SID | sid | System identification (from the SID parameter) | |
SMF75TME SMF75DTE | endTime | Datetime when the record was moved into the SMF buffer | |
SMF75MFV | rmfVersion | RMF version number | |
SMF75PRD | productName | Product name ('RMF') | |
SMF75IST SMF75DAT | startTime | Datetime when the RMF measurement interval started | |
SMF75INT | seconds | Duration of the RMF measurement interval | second |
SMF75SAM | rmfSamples | Number of RMF samples | |
SMF75MVS | mvsLevel | MVS software level (ZVvvrrmm) | |
SMF75SYN | syncVal | SYNC value | second |
SMF75XNM | sysplex | Sysplex name (in the COUPLExx parmlib member) | |
SMF75SNM | systemName | Sytem name (r in the IEASYSxx parmlib member) | |
SMF75DSN | pageName | Page data set name | |
SMF75PST | pageType | Page space type Bit Meaning When Set
| |
SMF75VOL | pageVol | Volume serial number | |
SMF75BDS | unusableSlots | Number of unusable slots | |
SMF75USE | asmSamples | Number of samples indicating data set was being used by ASM | |
SMF75REQ | reqSamples | The value is the same as SMF75USE | |
SMF75SIO | ioRequest | Number of I/O requests for the data set | |
SMF75PGX | pageTransfer | Number of pages transferred to or from page data set | |
SMF75LVU | usedSlots | Average number of slots used. Same as SMF75AVU, but long floating point format |