SMF 74-4 Structure Data
    • 28 Feb 2024
    • 1 Minute to read
    • Contributors
    • Dark
      Light

    SMF 74-4 Structure Data

    • Dark
      Light

    Article summary

    Introduction

    Fields

    Stored in cfnStrData

    SMF FieldDB Column nameDescriptionUnit
    recordTypeValue is always XCSD
    SMF74SIDsidSystem identification (from the SID parameter)
    SMF74GIEstartTimeProjected gathering interval end GMT time
    SMF74TMEendTimeTime since midnight, in hundredths of a second, that the record was moved into the SMF buffer
    SMF74INTsecondsDuration of the RMF measurement intervalsecond
    SMF74MFVrmfVersionRMF Version number
    SMF74PRDproductNameProduct name (‘RMF’)
    SMF74MVSmvsLevelMVS software level (ZVvvrrmm)
    SMF74IMLprocessorTypeIndicates the type of processor complex on which data measurements were taken
    SMF74PRFprocessorFlagsProcessor flags (1, 2, 3, 4, 5, 6 or 7)
    offset
    SMF74SYNsynctimeSYNC valuesecond
    SMF74XNMsysplexSysplex name ( in the COUPLExx parmlib member)
    SMF74SNMsysnameSystem name (r in the IEASYSxx parmlib member)
    R744QSTRcfStrNameName of structure allocated in this coupling facility
    R744QSIZcfStrSizeReqStructure size requested to be allocated4 kilobyte
    R744QVERcfStrVersionStructure version number
    R744QFLGcfStrFlagsStatus Flags
    R744QFL1cfStrFlag10 means Duplexing is active using system-managed asynchronous duplexing
    actionId
    R744FNAMElcfCFNameName of coupling facility as defined in parmlib member COUPLExx

    Changing your password will log you out immediately. Use the new password to log back in.
    First name must have atleast 2 characters. Numbers and special characters are not allowed.
    Last name must have atleast 1 characters. Numbers and special characters are not allowed.
    Enter a valid email
    Enter a valid password
    Your profile has been successfully updated.