SMF 74-4 Request CF Data
    • 28 Feb 2024
    • 2 Minutes to read
    • Contributors
    • Dark
      Light

    SMF 74-4 Request CF Data

    • Dark
      Light

    Article summary

    Introduction

    Fields

    Stored in cfnRqData

    SMF FieldDB Column nameDescriptionUnit
    recordTypeValue is always XCRQ
    SMF74SIDsidSystem identification (from the SID parameter)
    SMF74GIEstartTimeProjected gathering interval end GMT time
    SMF74TMEendTimeAdded descriptions of some columns
    SMF74INTsecondsDuration of the RMF measurement intervalsecond
    SMF74MFVrmfVersionRMF Version number
    SMF74PRDproductNameProduct name (‘RMF’)
    SMF74MVSmvsLevelMVS software level (ZVvvrrmm)
    SMF74IMLprocessorTypeIndicates the type of processor complex on which data measurements were taken
    SMF74PRFprocessorFlagsProcessor flags (1, 2, 3, 4, 5, 6 or 7)
    offset
    SMF74SYNsynctimeSYNC valuesecond
    SMF74XNMsysplexSysplex name ( in the COUPLExx parmlib member)
    SMF74SNMsysnameSystem name (r in the IEASYSxx parmlib member)
    R744SNAMcfRqSNameName of connected structure in this coupling facility
    R744SVERcfRqSVerStructure version number
    R744STYPcfRqStype
    1. Unserialized List structure
    2. Serialized List structure
    3. Lock structure
    4. Cache structure
    R744SFLGcfRqSFlag
    1. Structure was connected to the system at the end of the interval
    2. Structure became active during the interval
    3. Structure is capable to participate in asynchronous duplexing
    4. Structure is in the duplexing active state
    5. Structure is primary instance of an asynchronously duplexed structure
    6. Structure is secondary instance of an asynchronously duplexed structure
    7. Structure is encrypted
    R744SLECcfRqSLockLock structure only: lock table entry characteristic
    R744SLELcfRqSListLim
    • List structure, limit on number of list entries
    • Lock structure, limit on number of data elements
    R744SLEMcfRqSListCurList structure, current number of list entries in use
    R744SLTLcfRqSLockLimLock structure only, limit on number of lock table entries
    R744SLTMcfRqSLockCurLock structure only, Current number of lock table entries in use
    R744SSTAcfRqSSynctoAssyncThe number of list, lock, or cache requests that were to be executed synchronously at the coupling facility, but which were changed to an asynchronous operation due to lack of resources
    R744STRCcfRqSTotReqThe total number of IXLLIST, IXLCACHE, or IXLLOCK requests made
    R744STACcfRqSTotLockReqDelayedThe total number of IXLLOCK requests that could not be satisfied immediately because of lock contention
    R744SARCcfRqSTotReqAssyncThe total number of operations executed asynchronously at the coupling facility
    R744SATMcfRqSTotServTimeAssyncSummed service time for asynchronous requestsmicrosecond
    R744SSRCcfRqSTotReqSyncNumber of synchronous requests
    R744SSTMcfRqSTotServTimeSyncSummed service time for synchronous requests in microsecondsmicrosecond
    R744SSSQcfRqSTotSrqServTimeSyncSummed squares of service time for synchronous requests
    R744SQRCcfRqSNumTimesQueReqNumber of queued requests
    R744SCNcfRqSNumTimesLockContLock structure only, number of times any request encountered lock contention
    R744SFCNcfRqSNumTimesFalseLockContLock structure only, number of times any request encountered false lock contention (storage contention within the structure)
    R744SSIZcfRqSAllocSizeAllocated size of structure4 kilobyte
    R744SMAScfRqSMaxStrucSizeMaximum structure size
    R744SMIScfRqSMinStrucSizeMinimum structure size
    R744SDECcfRqSTotDirEntryCache structure only, total directory entry count
    R744SDELcfRqSTotDataElemCache structure only, total data element count
    R744SNLHcfRqSNumListHeaderList structure only, number of list headers
    R744SMAEcfRqSMaxNumElemList structure only, maximum number of elements. The estimated maximum number of list elements that may reside in storage class memory is not included
    R744SETMcfRqSExecTimeStructure execution time. Valid if R744FLVL > 14microsecond
    R744SOSAcfRqSSucOpeSCMNumber of successful operations to the coupling facility that encountered an SCM Access Required condition
    actionId
    R744FNAMElcfCFNameName of coupling facility as defined in parmlib member COUPLExx

    Changing your password will log you out immediately. Use the new password to log back in.
    First name must have atleast 2 characters. Numbers and special characters are not allowed.
    Last name must have atleast 1 characters. Numbers and special characters are not allowed.
    Enter a valid email
    Enter a valid password
    Your profile has been successfully updated.