    Article summary

    Introduction

    Fields

    Stored in cacheData

    SMF FieldDB Column nameDescriptionUnit
    recTypeValue is always CHE
    SMF74DATstartTimeDate when the RMF measurement interval started
    SMF74ISTstartTimeTime when the RMF measurement interval started
    SMF74DTEendTimeDate when the record was moved into the SMF buffer
    SMF74TMEendTimeTime when the record was moved into the SMF buffer
    SMF74INTsecondsDuration of the RMF measurement intervalsecond
    SMF74SIDsidSystem identification (from the SID parameter)
    SMF74XNMsysplexSysplex name ( in the COUPLExx parmlib member)
    SMF74SNMsystemNameSystem name (r in the IEASYSxx parmlib member)
    R745DVOLvolserVolume serial of device
    R74CCMTstorageArrayType and Model
    R745DEVNdevnumDevice number
    R745DSIDssidSubsystem ID
    R74CCMTtypeNumFirst element of storageArray
    R74CCMTmodelNumSecond element of storageArray
    R74CCMTmanufactureThird element of storageArray
    R74CCMTplantFourth element of storageArray
    R74CCMTseqNumFifth element of storageArray
    R745DVIDtagStorage Tag + Device Address
    R745SDEVcuDevnumCU Device number
    R745SDIDcuTagStorage Tag + CU Device ID
    R7451XIDxpidExtension Pool ID
    R7452XTYxpTypeExtension Type + XFL
    R745DRCRcacheReadRead Cache Request
    R745DCRHcacheReadHitRead Cache HITS
    R745DWRCcacheWriteWrite Cache Request
    R745DWCHcacheWriteHitWrite Cache HITS
    R745DICLcacheInhibitInhibit Cache Load
    R745DBCRcacheBypassBypass Cache Request
    R745DRSRseqReadRead Sequence Request
    R745DRSHseqReadHitRead Sequence HITS
    R745DWSRseqWriteWrite Sequence Request
    R745DWSHseqWriteHitWrite Sequence HITS
    R7452PROphyReadPhysical Read
    R7452PWOphyWritePhysical Write
    R7452PBRphyReadBytePhysical Read Bytes
    R7452PBWphyWriteBytePhysical Write Bytes
    R7452PRTphyReadRtPhysical Read R.T.
    R7452PWTphyWriteRtPhysical Write R.T.
    R7451CT1byteReadBytes read
    R7451CT2byteWriteBytes write
    R7451CT3byteReadRtRead reponse time
    R7451CT4byteWriteRtWrite response time
    R745DRNRnretReadRead non-retentive
    R745DNRHnretReadHitRead non-retentive HITS
    R745DWNRnretWriteWrite non-retentive
    R745DWNHnretWriteHitWrite non-retentive HITS
    R745DTCxfrSeqDasdSequence DASD to XFR
    R745DNTDxfrNormDasdNormal DASD to XFR
    R745DCTDxfrCacheDasdCache DASD to XFR
    R745DFWBfwBypassFast Write Bypass
    R745DFWCfwCacheF.W. Cache Request
    R745DFWSfwSeqF.W. Sequence Request
    R745DCRMrecCacheMissRecord Cache Miss
    R745DCWPrecCacheWrProRCD Cache Write Pro
    R7452RMRrecModeReadRecord Mode Read
    R745DKDWckdWriteCKD Write
    R745DKDHckdWriteHitCKD Write HITS
    R745DFWRcfwBypassCFW Bypass
    R7451RSVlowIntRtLower Interference R.T.
    R7451CT5zhpfReadZHPF Read I/O
    R7451CT6zhpfWriteZHPF Write I/O
    R7451XSFxrcReadXRC or CC Read
    R7451XCWxrcWriteXRC or CC Contaminated writes
    R7451TSPpprcTrackNumber of tracks transferred to secondary Peer-to-Peer-Remote-Copy(PPRC) volume
    actionId
    cec_name
    cec_type
    cec_model
    lpar_name

    Changing your password will log you out immediately. Use the new password to log back in.
    First name must have atleast 2 characters. Numbers and special characters are not allowed.
    Last name must have atleast 1 characters. Numbers and special characters are not allowed.
    Enter a valid email
    Enter a valid password
    Your profile has been successfully updated.