--- title: "ZETALY Automated Capacity© overview" slug: "zetaly-automated-capacity-overview" updated: 2024-05-02T14:32:12Z published: 2024-05-02T14:38:23Z canonical: "docs.zetaly.io/zetaly-automated-capacity-overview" --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.zetaly.io/llms.txt > Use this file to discover all available pages before exploring further. # ZETALY Automated Capacity© overview *This chapter presents ZETALY® product ZETALY Automated Capacity©, version 4.5.00.* ## ZETALY Automated Capacity© environment ### Collection environment **ZAC Collector** ZETALY Automated Capacity© collects metrics using its own collector (ASC). One ZAC collector STC must be started on every z/OS image. **ZAC Monitor** At each interval (the running frequency of the algorithm – the Policy Adjustment of ZAC), the ZAC Monitor retrieves data from ZAC Collectors such as R4H, DC, IMSU, Weight, number of logical processors, WLM Capping percentage for each LPAR and serial number, family, type, number of CPs for each CPC. In addition, the ZAC collector provides WLM service class and tenant resource groups information. ### Setting environment At each interval (the running frequency of the algorithm), ZAC decides to change (or not) the z/OS image defined capacity (DC). There are 2 ways to execute those changes: **BCPii** - The BCPii feature is available on z/OS 1.11 and higher **HMC API** - Configure the API and allow the HMC to be accessed via the network ### Network environment If you plan to use BCPii setting method, there are no network prerequisites. If you plan to use HMC setting method, ask your Network Specialist for routing availability between the various z/OS images, and between ZETALY Automated Capacity© z/OS images and the HMC. If a Firewall is used, make sure the SNMP protocol is opened between ZETALY Automated Capacity© z/OS images and the HMC. More information is available in chapter [7:](/docs/zetaly-automated-capacity-overview#_bookmark107) “[Enabling communication with the HMC](/docs/zetaly-automated-capacity-overview#_bookmark107)”. ## ZETALY Automated Capacity© architecture ### General architecture The ZETALY Automated Capacity© product consists of three parts: - The “**Monitor**” (main STC) controls the entire process. It runs permanently on one LPAR and executes cyclically (the frequency depends on the “INTERVAL” parameter); - The “**Collectors**” which are ZAC agents (collector STC); - The “**Reporter**” (HTTP server STC), which allows access to graphs and tables via a web browser - Internet explorer 11. Recommended version is IE 11 - Mozilla Firefox 42+ - Google Chrome 30+ Each cycle collects data, analyses LPAR behavior, sets LPAR capacity (or not), updates report files, sends alarms (or not) and writes SMF records. **Operator** *Figure 1 ZAC Architecture* ![](https://cdn.document360.io/a74c9756-0e82-4b64-bffd-236c17c00cbd/Images/Documentation/zetaly-automated-capacity-overview-image-mjtfs96v.png?sv=2026-02-06&spr=https&st=2026-11-18T15%3A01%3A36Z&se=2026-11-18T16%3A01%3A36Z&sr=b&sp=r&sig=lC%2FsPdmpL1Xcvgz1FG6ghSjJvr4Zz%2B%2B5eq%2Bp6vJgqwQ%3D)![](https://cdn.document360.io/a74c9756-0e82-4b64-bffd-236c17c00cbd/Images/Documentation/zetaly-automated-capacity-overview-image-zmnw6p35.png?sv=2026-02-06&spr=https&st=2026-11-18T15%3A01%3A36Z&se=2026-11-18T16%3A01%3A36Z&sr=b&sp=r&sig=N70ZqFef%2Bqs27up06q8SaGcwVikLKSI2qlVkzNrQPEs%3D)![](https://cdn.document360.io/a74c9756-0e82-4b64-bffd-236c17c00cbd/Images/Documentation/zetaly-automated-capacity-overview-image-v9ydckuc.png?sv=2026-02-06&spr=https&st=2026-11-18T15%3A01%3A36Z&se=2026-11-18T16%3A01%3A36Z&sr=b&sp=r&sig=LlJ65cROovwao09UEEa6LxxSE%2FwlTNzpssWfjedvc%2Bs%3D)![](https://cdn.document360.io/a74c9756-0e82-4b64-bffd-236c17c00cbd/Images/Documentation/zetaly-automated-capacity-overview-image-of7mbnti.png?sv=2026-02-06&spr=https&st=2026-11-18T15%3A01%3A36Z&se=2026-11-18T16%3A01%3A36Z&sr=b&sp=r&sig=QGpZ2rQSJTrhTH95j%2B%2BBixW%2BF7fURbbumsWI1QamyPI%3D)![](https://cdn.document360.io/a74c9756-0e82-4b64-bffd-236c17c00cbd/Images/Documentation/zetaly-automated-capacity-overview-image-e12s2ye0.png?sv=2026-02-06&spr=https&st=2026-11-18T15%3A01%3A36Z&se=2026-11-18T16%3A01%3A36Z&sr=b&sp=r&sig=WKnjjfW7n8shtmfYm02WiaIdl0mMqedyADIyk2Eq6UE%3D)![](https://cdn.document360.io/a74c9756-0e82-4b64-bffd-236c17c00cbd/Images/Documentation/zetaly-automated-capacity-overview-image-ypq070e2.png?sv=2026-02-06&spr=https&st=2026-11-18T15%3A01%3A36Z&se=2026-11-18T16%3A01%3A36Z&sr=b&sp=r&sig=pKctqPndaZ8NALjJ1XW4c1wfM3e9hK9mcxp5yd9XvUg%3D)![](https://cdn.document360.io/a74c9756-0e82-4b64-bffd-236c17c00cbd/Images/Documentation/zetaly-automated-capacity-overview-image-a52s3p4a.png?sv=2026-02-06&spr=https&st=2026-11-18T15%3A01%3A36Z&se=2026-11-18T16%3A01%3A36Z&sr=b&sp=r&sig=84tjDipshMN4HI2XX464iAqx7fQ%2BRDXxBvx7KA10jbU%3D) **MONITOR** ZCASC : main ASC started task **Data gathering (collect)** - **LPARs**: DC, IMSU, R4H, WLM Capping, WLM Service Class MSUs, importances MSUs, … - **CPCs**: capacity, CPs, … **LPAR behavior analysis** Elaborates DC changes strategy **LPAR settings** Via BCPii or HMC API **Web reporting** Update HTML data files **Alert sending** WTO, emails, CMD **Web browser** From IE11, Firefox 42 or Chrome 30 upwards. **SMF records writing** 225 by default **Metrology** ZETALY Streaming Agent, TDS - SAS/MXG, TBA, other **ASC REPORTER** ZCASCW IBM Web Server DOMINO or APACHE **ASC Commands** **Period definitions** **ASC parameters** **ASC COLLECTOR AGENT** DC, IMSU, R4H, WLM Capping, WLM Service Class MSUs, Importances MSUs, Tenant resource groups consumtions,…. ### ZETALY Automated Capacity© typical configuration sample - One ZAC monitor (ZCASC) for two CPCs. This example shows one monitor, which manages two CPCs (a maximum of eight CPCs can be managed by one monitor). Another way is to start one monitor per CPC. Thus, when you stop the monitor, only one CPC and the LPARs belonging to it are impacted. In CMP mode you must start only one monitor to manage the entire CMP. - One ZAC Web Reporter (ZCASCW) per ZAC monitor - One ZAC Collector (ZCASCCOL) per LPAR managed by the ZAC monitor ![](https://cdn.document360.io/a74c9756-0e82-4b64-bffd-236c17c00cbd/Images/Documentation/zetaly-automated-capacity-overview-image-ic53smfd.png?sv=2026-02-06&spr=https&st=2026-11-18T15%3A01%3A36Z&se=2026-11-18T16%3A01%3A36Z&sr=b&sp=r&sig=GhjqtV8HuQ3lsUsru31RDa9FBeqaiaxI039hY%2B0ew0I%3D) *Figure 2 Typical ZAC Configuration*